CY2308SC-1H Datasheet Download

Part No.:
CY2308SC-1H
Download:
Download Datasheet
Description:
[3.3V Zero Delay Buffer]
File Size:
367 K
Page:
15 Pages
Logo:
Manufacturer:
CYPRESS [ CYPRESS SEMICONDUCTOR ]
PCB Prototype
 CY2308SC-1H Datasheet Page:1CY2308SC-1H Datasheet Page:2CY2308SC-1H Datasheet Page:3CY2308SC-1H Datasheet Page:5CY2308SC-1H Datasheet Page:6CY2308SC-1H Datasheet Page:7CY2308SC-1H Datasheet Page:8CY2308SC-1H Datasheet Page:9 
CY2308
Maximum Ratings
Supply Voltage to Ground Potential................–0.5V to +7.0V
DC Input Voltage (Except Ref) .............. –0.5V to V
DD
+ 0.5V
DC Input Voltage REF ........................................... –0.5 to 7V
Storage Temperature .................................. –65°C to +150°C
Junction Temperature .................................................. 150°C
Static Discharge Voltage
(MIL-STD-883, Method 3015).................................... >2000V
Operating Conditions for Commercial Temperature Devices
Parameter
V
DD
T
A
C
L
C
IN
t
PU
Supply Voltage
Operating Temperature (Ambient Temperature)
Load Capacitance, below 100 MHz
Load Capacitance, from 100 MHz to 133 MHz
Input Capacitance
Power up time for all V
DD
s to reach minimum specified voltage
(power ramps must be monotonic)
Description
Min
3.0
0
0.05
Max
3.6
70
30
15
7
50
Unit
V
°C
pF
pF
pF
ms
Electrical Characteristics for Commercial Temperature Devices
Parameter
V
IL
V
IH
I
IL
I
IH
V
OL
V
OH
I
DD
(PD mode)
I
DD
Description
Input LOW Voltage
Input HIGH Voltage
Input LOW Current
Input HIGH Current
Output LOW Voltage
Output HIGH Voltage
V
IN
= 0V
V
IN
= V
DD
I
OL
= 8 mA (–1, –2, –3, –4)
I
OL
= 12 mA (–1H, –5H)
I
OH
= –8 mA (–1, –2, –3, –4)
I
OH
= –12 mA (–1H, –5H)
Unloaded outputs, 100 MHz REF,
Select inputs at V
DD
or GND
Unloaded outputs, 66 MHz REF
(–1, –2, –3, –4)
Unloaded outputs, 33 MHz REF
(–1, –2, –3, –4)
Test Conditions
Min
2.0
2.4
Max
0.8
50.0
100.0
0.4
12.0
45.0
70.0
(–1H,–5H)
32.0
18.0
Unit
V
V
μA
μA
V
V
μA
mA
mA
mA
mA
Power Down Supply Current REF = 0 MHz
Supply Current
Note
6. Applies to both Ref Clock and FBK.
7. Parameter is guaranteed by design and characterization. Not 100% tested in production.
Document Number: 38-07146 Rev. *E